How to verify the size of the enameled wire(c)

2015-11-17

Conductor size.

Removed by any method of the enameled wire (round) when the the Conductor nominal diameter d ≤ 0.200mm, in the 3 position of each 1m apart does not damage the conductor insulation of each measurement of a conductor diameter: average value as the conductor diameter.

When the the Conductor nominal diameter d> O. 200mm, removing any method does not damage the conductor insulation, equalization along the conductor circumference three positions were measured, whichever is the average of the three measured values ​​as a conductor diameter.

Enameled wire (flat wire) apart of each 10Omm3 position, removed by any of the methods does not damage the conductor insulation, were measured broadside and Narrow size 1, whichever is the average of the three measured values as broadside and Narrow conductor size.